      The Slide Table Control (Manuel) Function 
		  controls the operation of a Manuel slide table. 
		  This is useful when the part to be printed and fixture are too tall to 
		  be removed under the Hot Stamping head or the Hot Stamping head is so 
		  large that the operator can not safety load and unload the part to be 
		  printed without burning them self. 
		   
		  When the Foil is set to pull before print it does the following: 
		  1. Operator loads the part to be printed onto the fixture. (The 
		  fixture is on the slide table and the table is in the out position) 
		  2. The Operator press both palm buttons at the same time 
		  3. The Slide Table moves to the in position. 
		  4. Hot Stamping head moves to the print position 
		  5. The Hot Stamping head stays down for the Print Time 
		  6. Hot Stamping head returns to the up position 
		  7. The Slide Table moves to the out position 
		  8. Operator removes printed part 
		   
		  Note: Operator must hold the palm buttons down until the Hot Stamping 
		  Head gets into the print position.  If the operator does not hold the buttons down the Hot Stamping Head will go back to the up 